King 5500m Pellet Stove Troubleshooting
King 5500m Pellet Stove TroubleshootingSee details Buy It Now Add to cart Watch Sold by keep_the_change ( 3461) 97. 5500 Series Owners Manual - US Stove Company | Wood Stoves. United States Stove King/Ashley 5500M Owner's Manual (24 pages) United States Stove Co. Replacement 80472 & 80472A Distribution Blower Fan for US Stove & USSC American Harvest 6039 6041, King KP130, 5502M, Ashley 5500 5500M 5500XL Pellet Stoves. 5500 Please read this entire manual before installation and use of this appliance. The Draft Fan (Exhaust Fan) output fuse has blown. King/Ashley Pellet Stove 5500 Please read this entire manual before installation and use of this appliance. US Stove 5500M King Pellet Burner with Igniter. Keep all such liquids well away from the stove while it is in use. The Control board is the brains of your pellet stove. Flashing dash in Heat Range Display: This indicates that the stove is in the normal run mode and is ramping from the current heat range setting to the target heat range setting. Replace if moist, wet, or dirty. USSC Pellet Stove Repair Videos. (80 pages) Pellet stove USSC Ashley AP5660 Installation And Operating Manual. Step 1: After removing the stove’s power source, empty the hopper of all pellets and clean the auger housing to clear Step 2: Examine the internal housing of the auger with a small mirror and a powerful flashlight to see where the auger Step 3: If you have access to the outer auger housing,. I have yet to figure out what these a/b/c buttons do, at first sight they seem to just set the heat range and blower speed at other settings. If your 5500 series pellet stove seems to have trouble feeding. Stove does not start a fire when the "ON" button is pushed • Turn the stove "OFF". Circuit board for models: 5500, 5500M, 5500XL. 80619 80481 - King Ashley Pellet Stove Igniter, Ignitor - 13-1115 FC 4. United States Stove KING/ASHLEY PELLET STOVE 5500M Owner's Manual (24 pages) United States Stove Co. Also for: 5500m, 5500xl. Flashing dash in Heat Range Display: This indicates that the stove is in the normal run mode and is ramping from the current heat range setting to the target heat range setting. If your 5500 series pellet stove seems to have trouble feeding pellets, indicated by a Buffing the Burnpot. United States Stove KING/ASHLEY PELLET STOVE 5500M Owner's Manual (24 pages) United States Stove Co. Product Description & Features: 5 heat settings allow the ability to adjust to your heating needs; 120 CFM. Problems with pellet stoves we’ve discussed and provided solutions for include: Shutting off Going out Backing up Burning black Smoking Smelling like smoke Not igniting Taking long to light Auger jamming Blowing cold air Not feeding pellets Overfeeding pellets Not burning pellets all the way Using many pellets Burn pot overflowing. Safety Precautions This manual describes the installation and operation of the King/Ashley, 5500, 5500XL, 5500M wood heater. If the low Limit has screw terminals, then prepare 2 wires with male clips on one end, stripping the other end to fasten under the screws. How to replace the 80619/80481 ignitor in. How to Adjust Feed Rate and Reset Pellet Stove and Tweak factory codes. com/watch?v=LcW6HiRQr0c&feature=youtu. The 5500M blends nicely with any room setting and. How to Troubleshoot a King Ashley 5500 Pellet Stove Straightforward Solutions. US Stove Feature Videos. Once the ramp is complete, the dash will stop flashing. This can prevent airflow through the system, causing the error code. beI installed this stove about a mo. Heat off the grid while staying on a budget with our efficient wood and pellet stoves. 5500M and 5500XL Note: All repair parts (other than Cabinet Sides, Hopper Assy. Observe the flames inside your wood pellet stove. Check for air leaks in the system, such as in the door gasket. Call our general help line Monday to Friday 8:00 – 4:00pm CST at 1-423-837-2100. Manufacturer: US Stove Company. Attach to male spade lugs available at Home Depot, Lowes or any big box store and crimp them onto the a wire at least a few inches long. Environmental Protection Agency's crib wood emission limits for wood heaters sold after May 15, 2015. This is the older model stove, that only has the LCD display of "Heat Range", "Blower Speed", and 3 buttons labeled "A, B and C". Stove Installation Videos. Our USSC Ashley and King vacuum switch replacement for 80549 will be correct for the 5500M, 5500XL, 5501S, 5510, AP130, AP5660L, AP5710, AP5780B, AP5780PS, AP5780SS, AP5790, AP60, KP130, and KP60 models. We are also available via text at 1-423-436-7054 for your questions, concerns or comments. I wasn't able to find a video on this so I did some experimenting on my own and found a way to turn the auger setting. Make sure that the viewing door is closed and sealed properly. Pellet Stoves Wood Stoves. King Pellet Stove Problems Part 1 - YouTube King Pellet Stove Problems Part 1 Guy Merritt 2. SOUTH PITTSBURG, TENNESSEE 37380. 5 (22) $9997 FREE delivery Mon, Apr 17 Only 16 left in stock - order soon. UNITED STATES STOVE COMPANY. United States Stove KING/ASHLEY PELLET STOVE 5500M Owner's Manual (24 pages) United States Stove Co. 5500m Pellet Stove. Failure to follow these instructions could result in property damage, bodily injury, or even death. Press the arrows again to adjust fan speed. Set the multi-meter meter to ohms. US Stove 5500M King Pellet Burner with Igniter. START-UP PROCEDURE Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove. Stove - Pellet Stove User Manual Brand: United States Stove | Category: Pellet stove | Size: 1. Clear the unburnt fuel from the burnpot and try again. 78 Add to Cart Search within model Questions & Answers Browse all Parts Search by Area Page A Page B Previous Showing All Parts Next Page A Hotspots Fig # 1 Feed Door Part Number:25507. Problems with pellet stoves we’ve discussed and provided solutions for include: Shutting off Going out Backing up Burning black Smoking Smelling like smoke Not igniting Taking long to light Auger jamming Blowing cold air Not feeding pellets Overfeeding pellets Not burning pellets all the way Using many pellets Burn pot overflowing. Instructional video showing how to clean and maintain the 5500M pellet stove. Quickly (changes twice per second) Flashing Heat Range Setting Indicator: This indicates that. 55 MB Table of Contents Table of Contents 2 Safety Precautions 3 Specifications 4 Heating Specifications 4 Dimensions 4 Electrical Specifications 4. Should any of you viewers have questions about this Pellet Stove Controller (or one like it), or. Solution: To resolve error code 1, begin by ensuring that the room is properly ventilated. If pellets won't slide, a light spray over the inside of the hopper with silicon lubricant will help. Switch the power back on, start the stove, and see whether or not the auger is turning. 99 SKU 88177 Ashley Ash Clean Out Gasket: 88177 12 reviews Add to cart $0. When the heater is in the manual mode, the optional thermostat will not properly control the unit. Fuel is having a hard time feeding into the burnpot. 0 4 product ratings 5 4 4 0 3 0. US Stove 5500M Pellet Stove Repair and Replacement Parts Find all the replacement stove parts & accessories you need for US Stove pellet stoves in our store. START-UP PROCEDURE Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove. USSC Pellet Stove Repair Videos. Inspect the system at the stove connection and at the chimney top. By looking at the wiring schematic of the Ashley 5500M, It looks as if the problem could be a number of the electrical parts of this unit. rOOM FAN • The room fan will come on once the unit has reached operating temperature. Owner's Manual 5502M. 80619 80481 - King Ashley Pellet Stove Igniter, Ignitor - 13-1115 FC 4. Heating Capacity2 800 - 2,000 sq. Contact your local building or fire officials about restrictions and installation inspection requirements in your area. The power failed while the stove was hot, and when power was restored, the fire was out. Pellet fuel-burning room heater (32 pages). KP130 / 5502M / 5500M Ignitor. US Stove 5500M King Pellet Burner with Igniter. This pellet stove can perform up to 48,000 BTUs and has a coverage area of up to 2,200 sq. Replacement control board for stoves Genuine USSC OEM part Easy Do-it-yourself repair Circuit board for models: 5500, 5500M, 5500XL Replaces model 80558 Product information Warranty & Support. Ashley 5500M Pellet Stove Repair and Replacement Parts Resources & Help $11. The stove was unable to reach the Room Fan On temperature within the startup time. When you start these pellet stoves the auger runs for exactly 1 minute then the ignitor comes on. Failure to follow instructions. This unit is not intended to be used as a primary source of heat. 5500 Series Owners Manual - US Stove Company | Wood Stoves. 5500 pellet stove pdf manual download. Troubleshooting You can make a male to male jumper to bypass this switch temporarily to see if the stove continues to run with no error # 3 light. Check for air leaks in the system, such as in the door gasket. US Stove Company 5500M King/Ashley Pellet Stove Parts $9. It's possible your draft fan is weak or your stove needs more cleaning. they are in the same room as the stove. Flashing Aux Indicator: This indicates that the ignitor is on during the lighting stage. Environmental Protection Agency. Verify the igniter rod is positioned correctly. The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes. 5500 Series Owners Manual - US Stove Company | Wood Stoves. I wasn't able to find a video on this so I did some experimenting on my own and found. Open the hopper door on the top of the stove and remove the remaining pellets from the hopper bin. I bought a "new" 2006 King 5500m pellet stove 3 months ago. 58 Add to Cart Add to Cart Add to Cart Add to Cart $208. But it revs up ea time 1-2-3 but no more at all when I go 4-9 on room blower fan. Whatever the problem you are struggling with, you can quickly fix that by reading our King Pellet stove troubleshooting guide. Flashing dash in Heat Range Display: This indicates that the stove is in the normal run mode and is ramping from the current heat range setting to the target heat range setting. Heat off the grid while staying on a budget with our efficient wood and pellet stoves. Pellet stove USSC 5500 Owner's Manual. Furnace Repair and Maintenance. An electrical open exists in an over-temperature switch or wire. Page 4: Safety and EPA Compliance Specifications Heating Specifications Heat Output1 48,000 BTU/hr. Easy Do-it-yourself repair. Your stove is equipped with an automatic ignition system that should ignite the fuel within 5-10 minutes from pressing the ON button. Furnace Repair and Maintenance. Brand: US Stove Company. The vacuum switch is sensing air pressure in. Pellet USSC Pellet Stove Repair Videos. Stove designs & engineers our products in South Pittsburg, Tennessee. Stove - Pellet Stove User Manual Brand: United States Stove | Category: Pellet stove | Size: 1. Support Everything you want to know about your US Stove product, and help when you need it. Ensure the air-to-pellet. This pellet stove can perform up to 48,000 BTUs and has a coverage area of up to 2,200 sq. Stove Installation Videos. As pellets enter the burn pot and ignite, outside air is drawn across the fuel and heated during the combustion process which is then pulled through the heat exchanger by the exhaust motor or draft fan. How to reset your USSC Pellet Stove Controller Hi to all USSC Pellet Stove Owners. The Room Fan output fuse has blown. Flashing Off Indicator: This indicates that the stove is in the “Shutdown” state waiting for the OFF button, or for a 15 minute period after the stove was turned off, or for the stove to cool down, or for the door to be closed. Flashing dash in Heat Range Display: This indicates that the stove is in the normal run mode and is ramping from. US Stove 5500M King Pellet Burner with Igniter Product Description & Features: 5 heat settings allow the ability to adjust to your heating needs 120 CFM blower with automatic circulation to spread heat evenly Digital control board allows adjusting heat and draft control with the push of a button LED display makes it easier to set and operate. LED display makes it easier to set and operate. US Stove Company 5500M King/Ashley Pellet Stove Parts $9. The room's fan has stopped working. Right now whats happening is at the 1 minute time the board sends power to the ignitor for about 1second that i see with my meter and then it shuts down with the error code 6. The common King pellet stove problems include stove not igniting, stove not feeding, poor burn quality, shutting down, low heat, lazy flame, and many more. The following are some possible reasons why your King pellet stove isn't working. Breckwell Products Repair Videos. 120 CFM blower with automatic circulation to spread heat evenly. 57 Add to Cart Gasket, Exhaust Blower $11. Troubleshooting You can make a male to male jumper to bypass this switch temporarily to see if the stove continues to run with no error # 3 light. King/Ashley Pellet Stove 5500 Please read this entire manual before installation and use of this appliance. King/Ashley Pellet Stove. Heat the low limit switch until a click is heard which means the switch has closed. pellet capacity that allows extended operation for many days between fill-ups. 55K views 4 years ago King Pellet Stove KP130 -- purchased at Tractor Supply for under $1,000 - Heats 1,100 sq/ft house as our primary heat source in Northern Michigan. It is better to leave the stove in the automatic mode. 120 CFM blower with automatic circulation to spread heat evenly. We have 1 United States Stove KING/ASHLEY PELLET STOVE 5500M manual available for free PDF download: Owner's Manual. Ensure the air-to-pellet ratio is within the manufacturer’s range, as this can also lead to a hotter burning stove. The 5500M is a fully automatic pellet stove with auto ignition and easy to use digital controls. King/ashley pellet stove (24 pages) Pellet stove USSC 5520 Owner's Manual. The common King pellet stove problems include stove not igniting, stove not feeding, poor burn quality, shutting down, low heat, lazy flame, and many more. Do not connect the pellet vent to a vent serving any other appliance or stove. Breckwell Products Repair Videos. When you start these pellet stoves the auger runs for exactly 1 minute then the ignitor comes on. Certified to comply with 2015 particulate emissions standards. Our geniune OEM parts allow for easy do-it-yourself maintenance and repair. The Ignitor output fuse has blown. United States Stove KING/ASHLEY PELLET STOVE 5500M Owner's Manual (24 pages) United States Stove Co. This pellet stove can perform up to 48,000 BTUs and has a coverage area of up to 2,200 sq. The power to the feed motor is being interrupted, 3. 27K subscribers Subscribe Share 75K views 8 years ago I just uploaded another video of this thing. The feed motor is slowing down as the stove heats up, 2. Stove Not Feeding Pellets The king pellet stove not feeding pellets for several reasons. pellet capacity that allows extended operation for many days between fill-ups. 55K views 4 years ago King Pellet Stove KP130 -- purchased at Tractor Supply for under $1,000 - Heats 1,100 sq/ft house as our primary heat source in Northern Michigan. The power failed while the stove was hot, and when power was restored, the fire was out. • Check the pellet quality. If your stove is giving you an E2 Error, wait for the stove to cool (as applicable) and follow these steps: Clean the burnpot – remove dust, debris, and pellets for a thorough cleaning. If your 5500 series pellet stove seems to have trouble feeding pellets, indicated by a Buffing the Burnpot. Cooler surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top as. How to Adjust Feed Rate and Reset Pellet Stove and Tweak factory codes. What should happen is the draft fan should pull in air past the igniter through the large hole in the back of the burnpot and then through the pellets. Page 3; Page 4 Installation Installation Options Read this entire manual before you install and use your pellet stove. Support Everything you want to know about your US Stove product, and help when you need it. What should happen is the draft fan should pull in air past the igniter through the large hole in the back of the burnpot and then through the pellets. Ensure the igniter isn’t plugged in with ash. Our manufacturing utilizes components sourced both domestically and globally for assembly in. The flames should be bright yellowish-orange and burn without producing a black tip along the top of the flame. 49 SKU FEMALE-TO-FEMALE-12-INCH. I have yet to figure out what these a/b/c buttons do, at first sight they seem to just set the heat range and blower speed at other settings. 7% Positive feedback Contact seller About this product Learn more 5. This one had some display issues, and reported Erro. The reasons behind your king pellet stove not igniting are:. United States Stove KING/ASHLEY PELLET STOVE 5500M Manuals Manuals and User Guides for United States Stove KING/ASHLEY PELLET STOVE 5500M. Unplug the pellet stove from the electrical outlet. How to Troubleshoot a King Ashley 5500 Pellet Stove Straightforward Solutions. Final Test of Justin's USSC Brand Pellet Stove Controller - Err9 / Error 9. This is the older model stove, that only has the LCD display of "Heat Range", "Blower Speed", and 3 buttons labeled "A, B and C". Step 1: After removing the stove’s power source, empty the hopper of all pellets and clean the auger housing to clear Step 2: Examine the internal housing of the auger with a small mirror and a. Connect the meter leads to the low limit snap disc. • Do not connect the pellet vent to a vent serving • The hopper and stove top will be hot during any other appliance or stove. Product Description & Features: 5 heat settings allow the ability to adjust to your heating needs; 120 CFM blower with automatic circulation to spread heat evenly; Digital control board allows adjusting heat and draft control with the push of a button; LED display makes it easier to set and operate. King Pellet Stove Troubleshooting [ 7 Easy Solutions] 1. ) are same for models 5500, 5500M and 5500XL. Wood stove and Circulator Repair and maintenance. If your stove is giving you an E2 Error, wait for the stove to cool (as applicable) and follow these steps: Clean the burnpot – remove dust, debris, and pellets for a thorough cleaning. For added functionality and convenience, this US Stove 5500M comes with a 120 CFM blower, easy-to-use electronic controls, and a large hopper with a 120 lbs. 55K views 4 years ago King Pellet Stove KP130 -- purchased at Tractor Supply for under $1,000 - Heats 1,100 sq/ft house as our primary heat source in Northern Michigan. Address any leaks as necessary. This is the older model stove, that only has the LCD display of "Heat Range", "Blower Speed", and 3. The 5500M is a fully automatic pellet stove with auto ignition and easy to use digital controls. The 5500M is a fully automatic pellet stove with auto ignition and easy to use digital controls. The vacuum switch is sensing air. It is a durable design, built for years of high performance. Use and Care Manual - US Stove Company | Wood Stoves. When the stove produces a weak flame or a flame that is orange rather than blue, buildup in the Exhaust. When the stove produces a weak flame or a flame that is orange rather than blue, buildup in the Exhaust. Trouble Shooting Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does not disconnect all power to the electrical. This video is a repair update for Thomas, who sent me his USSC 5500M Pellet Stove Controller model 80558. If pellets won't slide, a light spray over the inside of the hopper with silicon lubricant will help. King Pellet Stove TESTED & LISTED BY Report #: 215-S-05c-2 • Please read this entire manual before installation and use of this appliance. Verify that the hopper is clean and free of foreign matter. We have 1United States Stove King/Ashley 5500M manual available for free PDF download: Owner's Manual. It may be a problem with the pressure switch,. For ramping from heat range 1 to 5, the default time is 12 minutes (with a 90 second ramp time). I bought a "new" 2006 King 5500m pellet stove 3 months ago. Manufacturer: US Stove Company. Step 1: After removing the stove’s power source, empty the hopper of all pellets and clean the auger housing to clear Step 2: Examine the internal housing of the auger with a small mirror and a powerful flashlight to see where the auger Step 3: If you have access to the outer auger housing,. KP130 / 5502M / 5500M Ignitor Replacement. The 5500M blends nicely with any room setting and provides your home with great heat. Use and Care Manual - US Stove Company | Wood Stoves. This safety sensor is also referred to as an air switch, pressure switch, or low draft sensor. 0 Page 5: Floor Protection Installation Installation Options Read this entire manual before you install and use your King/Ashley stove. 2019 & Earlier Owner's Manuals 2020 & Later Owner's Manuals. How to Troubleshoot a King Ashley 5500 Pellet Stove Straightforward Solutions. 453 55K views 4 years ago King Pellet Stove KP130 -- purchased at Tractor Supply for under $1,000 - Heats 1,100 sq/ft house as our primary heat source in Northern Michigan. US Stove 5500M King Pellet Burner with Igniter Product Description & Features: 5 heat settings allow the ability to adjust to your heating needs 120 CFM blower with automatic circulation to spread heat evenly Digital control board allows adjusting heat and draft control with the push of a button LED display makes it easier to set and operate. If your stove is giving you an E2 Error, wait for the stove to cool (as applicable) and follow these steps: Clean the burnpot – remove dust, debris, and pellets for a thorough cleaning. I see nothing in manual that shows I can reset or replace say a snap disc. This video is a repair update for Thomas, who sent me his USSC 5500M Pellet Stove Controller model 80558. Stove designs & engineers our products in South Pittsburg, Tennessee. 1 King KE40 King Catalytic KE1107 King KEJ1102 King KT1102 Princess 35 Princess 1010 Princess 1010A Princess PE1006 Princess PE32 Princess PEI1200 Princess PEJ1003 Princess PI29. United States Stove KING/ASHLEY PELLET STOVE 5500M Owner's Manual (24 pages) United States Stove Co. Replacement 80472 & 80472A Distribution Blower Fan for US Stove & USSC American Harvest 6039 6041, King KP130, 5502M, Ashley 5500 5500M 5500XL Pellet Stoves. Installation Materials are NOT Included. With the hopper empty, it's usually possible to see the auger. Heat off the grid while staying on a budget with our efficient wood and pellet stoves. Our geniune OEM parts allow for easy do-it-yourself maintenance and repair. The room isn't ventilated well enough. Do not install a flue damper in the exhaust venting system of this unit. How to Troubleshoot a King Ashley 5500 Pellet Stove Straightforward Solutions. Question my king pellet stove over heats if I go above heat 2 and it’s doing this because the room fan will only wrk 1-2-3 and when I put on numbers 4-9 it does not go any faster. Our manufacturing utilizes components sourced both domestically and globally for assembly in various manufacturing facilities both at home and abroad. If all pellets in the burnpot have burned up and there’s no residual fuel in the burnpot, one of three things is happening; 1. This video is a repair update for Thomas, who sent me his USSC 5500M Pellet Stove Controller model 80558. Our USSC Ashley and King vacuum switch replacement for 80549 will be correct for the 5500M, 5500XL, 5501S, 5510, AP130, AP5660L, AP5710, AP5780B, AP5780PS, AP5780SS, AP5790, AP60, KP130, and KP60 models. Stove Not Igniting The reasons behind your king pellet stove not igniting are: Lousy igniter The inappropriate flow 2. If your stove is giving you an E2 Error, wait for the stove to cool (as applicable) and follow these steps: Clean the burnpot - remove dust, debris, and pellets for a thorough cleaning. Manuals and User Guides for United States Stove King/Ashley 5500M. If air leaks out, it could cause the system to overheat as it tries to compensate. Without it, the pellet stove will not work. King Pellet Stove TESTED & LISTED BY Report #: 215-S-05c-2 • Please read this entire manual before installation and use of this appliance. King/Ashley Pellet Stove 5500 Please read this entire manual before installation and use of this appliance. Stove - Pellet Stove User Manual. Wood stove and Circulator Repair and. (28 pages) Pellet stove USSC 5660 Installation And Operating Manual. It's the hot air from the igniter that ignites the pellets. Digital control board allows adjusting heat and draft control with the push of a button. Brand: US Stove Company. How To Troubleshoot and Fix Common Pellet Stove Problems — Stove & Grill Parts For Less Items Browse By Collection Boxer 24 Chinook 30 Chinook 30C Chinook 30F Chinook 30. Safety Precautions This manual describes the installation and operation of the King/Ashley, 5500, 5500XL, 5500M wood heater. Enjoy our wide selection & fast shipping! Owner's Manual Parts List Resources & Help $1. 5500M Cleaning and Maintenance Video. I just uploaded another video of this thing smoking up the house:http://www. Our USSC Ashley and King vacuum switch replacement for 80549 will be correct for the 5500M, 5500XL, 5501S, 5510, AP130, AP5660L, AP5710, AP5780B, AP5780PS, AP5780SS, AP5790, AP60, KP130, and KP60 models. I bought a "new" 2006 King 5500m pellet stove 3 months ago. The stove was unable to reach the Room Fan On temperature within the startup time. Final Test of Justin's USSC Brand Pellet Stove Controller - Err9 / Error 9. The stove was unable to reach the Room Fan On temperature within the startup time. For added functionality and convenience, this US Stove 5500M comes with a 120 CFM blower, easy-to-use electronic controls, and a large hopper with a 120 lbs. Ensure the igniter isn't plugged in with ash. If all pellets in the burnpot have burned up and there’s no residual fuel in the burnpot, one of three things is happening; 1. The Auger output fuse has blown.